Auto Parts & Accessories
Computer Products
Electronic Components
Electronics
Fashion Accessories
Fashion Apparel & Fabrics
Furniture & Home Decor
Gifts & Premiums
Health & Personal Care
Home Appliances
Housewares
LED & Solar Products
Machinery & Parts

Communication Between Modbus-RTU and Profibus-DP Gateway hotel automation system

Price: 
pieces
105.00
1 + pieces
< >
Please select a Color
Please select a Size
- + piece
This product can't be shipped to the selected region by express delivery.If you want to buy this product,you can click inquire now to contact seller
Depends on the product properties you select

1.Product Introduction

 ODOT-DPM01 is a solution that provides a communication between Modbus-RTU and Profibus-DP protocols. Any Modbus-RTU devices, as long as it has RS485 interface, can connect to field bus Profibus-DP. Such as PLC, DCS, Distributed IO, frequency changer, motor protection devices, intelligent high and low voltage electrical equipment, electrical measuring devices, intelligent field measurement equipment and instrumentation.

2.Main Technical Parameters

1) Installation:35mm Standard rail

2) DP communication speed:9.6Kbps~12Mbps speed auto-sensing.

3) DP data area: input max.244bytes, output max. 244bytes, the sum of input and output is max. 456bytes.

4) DP slots: max.42

5) Modbus Master: Yes

6) Modbus Slave: Yes

7) Modbus station: 31

8) Mobus function code:01/02/03/04/05/06/15/16

9) Modbus baud rate:1200~115200bps

10) 8 data bits, No,Odd or Even parity,1 or 2 stop bits.

11) Supply voltage range:9~36 VDC, Max.50mA@24V

12) Operating temperature: -40~85℃

13) Storage temperature:-55~125℃

14) Relative Humidity:5~95%(No-condensation)

15) Dimension:104*25*102(L*W*H,mm)

16) IP grade:IP20

17) Certification:CE

3.Hardware wiring

1)Adopting pull out plug type screw terminal connection. Bottom of the module is 24V supply power and RS485 terminal(A+,B-), In front of the module there are status indicator, PROFIBUS-DP address DIP switch (m-16) and PROFIBUS-DP interface.

2)If high bits of Profibus-DP address set to 1 and low bits of Profibus-DP address set to 6,the address of this module in DP network:1*16+6=22,valid range of DP address:1-125.

3)Under normal conditions, ODOT-DPM01 Gateway status LED:

 PW:Power is supplied to the unit.

 DP:DP status,OFF- DP communications properly,Flashing-Not normal.

 TX:Flashing-Sending status of the RS485 interface.

 RX:Flashing-received status of the RS485 interface.

Sichuan Odot Automation System Co., Ltd

  • Phone: +86 0816-2530577
  • Business Type: Manufacturer
  • Location: China
  • Main Products: Protocol Converter,Industrial Ethernet Switch,Serial Device Server,Distributed IO,Industrial Switch
  • Total Employees:Less than 100 people
  • Year Established:2003
  • Export Markets:Domestic Market,Asia,Europe
  • Total Annual Revenue: